Web12 de set. de 2010 · API RP 14C recommends that a high pressure trip be present on the pump discharge. A low flow trip could be implemented as there are flow meters on each individual pump discharge, but there is some concern about the accuracy of the meters. … Web26 de ago. de 2016 · Jul 28, 2016. #1. HI, On our GE MS5001 gas turbine, we've observed that the lube oil bearing header pressure is 2.1bar when auxiliary pump (QA) is running but it drops to 1.5bar when the main lube oil pump which is shaft driven is running. the main lube oil pump discharge pressure is observed to be 6bar which is almost the same with …
Pump Overloading and its causes - EnggCyclopedia
Web13 de mai. de 2008 · Check running voltage and amps at load side of contactor. Heat pumps can trip on high press. if run in heat mode when outdoor temp. is above 70F or so. 05-13-2008, 11:04 PM #4. Timw. View Profile View Forum Posts Stainless Join Date Nov 2005 ... High discharge pressure comes from one of two problems about 99.99% of the time. Web4. Compressor discharge pressure high. This condition causes the compressor to overload the prime mover, and expose the high-pressure side of the system to overpressure; The system overpressure avoided by fitting a compressor motor trip and relief valve at the compressor outlet; Causes for discharge high pressure: Low coolant or air … grand home loans
Reasons for High Pressure / Low Pressure Trip outs [Archive ...
WebDischarge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the … Web12 de ago. de 2024 · August 12, 2024 by World Wide FAQS. One common cause of high discharge pressure is the cooling medium (air or water) flowing across the condenser: either there is not enough or the temperature of the cooling medium is too high. This is normally easy to identify with a simple visual inspection of the condenser. Web25 de nov. de 2015 · When we throttle the pump suction pressure we are actually controlling the flow-rate delivered by the pump in which we can also achieve the same effect by throttling at the pump discharge. That is why a good practice is to install flow control at the discharge of the pump. Centrifugal pumps trip is normally triggered by current due … chinese farming tools